National Instruments NI Vision NI 17xx 用户手册

下载
页码 90
Chapter 2
Power and I/O
2-2
ni.com
NI Smart Camera Power Requirements
Caution
Use the NI Smart Camera only with a 24 VDC, UL listed, limited power source 
(LPS) supply. The power supply should bear the UL listed mark, LPS. The power supply 
must meet any safety and compliance requirements for the country of use.
The smart camera uses a nominal 24 VDC power source. The smart camera 
accepts power within the range of the industry standard IEC 1311 input 
power specification (24 V +20%/–15% with an additional allowance for an 
AC peak of +5%). Refer to Appendix A, 
, for complete 
power requirement specifications.
Caution
The 24 V external lighting strobe is an unregulated output dependent on the range 
of the power supply provided to the smart camera. If the power provided to the smart 
camera is +20%/–15% with +5% AC ripple, the external lighting strobe output could be 
as high as 30 V. If the provided power exceeds the input voltage specifications of the 
third-party lighting controller, do not connect the 24 V lighting strobe output to the 
controller to prevent damage to the controller. Use a power supply with tolerances that 
meet the requirements of the controller, or use the 5 V external lighting strobe.
TrigIn–
IsoIn(0)–
IsoIn(1)–
12
Light Green
IsoOut(0)+
6
Yellow
IsoOut(0)–
1
Green
IsoOut(1)+
11
Light Blue
IsoOut(1)–
7
Gray
PhaseA+
3
Blue
PhaseA–
13
Brown/White
PhaseB+
9
Purple
PhaseB–
4
White
Table 2-1.  POWER-I/O Connector Signal Descriptions (Continued)
Connector Diagram
Signal Name
Pin Number
Wire Color
5 (+24 V)
15 (COM)
11
6
1
10