Chapter 2
Power and I/O
© National Instruments Corporation
2-3
If you are using the Direct Drive lighting controller, the power supply 
wattage must be sufficient to power both the camera and the light. The 
power required by the light can be significantly more than the power 
required by the smart camera.
Isolated Inputs
Caution
Do not apply a voltage greater than 30 VDC to the isolated inputs. Voltages 
greater than 30 VDC may damage the NI Smart Camera.
Caution
The isolated inputs and outputs on the smart camera provide an easy means for 
preventing ground loops that could degrade signal integrity. The isolation on the smart 
camera is not safety isolation.
You can wire an isolated input to both sourcing and sinking output devices. 
Refer to Figures 2-1 and 2-2 for wiring examples by output type. Refer to 
Appendix A, 
, for current requirements.
Isolated inputs are not compatible with 5 V logic.
Figure 2-1.  Connecting External Sourcing Output Sensors to Isolated Inputs
Sensor
Power
Sensor
Common
PNP (Sourcing)
Output Device
NI 17xx
TrigIn+
IsoIn(0)+
IsoIn(1)+
TrigIn–
IsoIn(0)–