LEDs and DIP Switches
6-4
ni.com
IMG ACQ LED
The IMG ACQ LED briefly lights green when an image is captured and 
ready for analysis. Fast frame rates can give this LED the appearance of 
being continuously lit.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that 
the NI Smart Camera has shut down because the maximum internal 
temperature was exceeded. Refer to the 
 section of 
, for information about 
measuring the temperature of the smart camera. Refer to Appendix A, 
, for complete specifications.
PASS LED
The PASS LED is a green LED that is user-configurable through the 
IMAQ property node in LabVIEW or the Read/Write I/O step in Vision 
Builder AI.
FAIL LED
The FAIL LED is a red LED that is user-configurable through the 
IMAQ property node in LabVIEW or the Read/Write I/O step in Vision 
Builder AI.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that 
the NI Smart Camera has shut down because the maximum internal 
temperature was exceeded. Refer to the 
 section of 
, for information about 
measuring the temperature of the smart camera. Refer to Appendix A, 
, for complete temperature specifications.
Configuring DIP Switches
This section describes the SAFE MODE, IP RESET, NO APP, and 
CONSOLE DIP switches on the NI Smart Camera. To turn on a DIP 
switch, lift the DIP switch cover and move the switch to the ON position.