TLM100 User’s Manual  
 
 
 
 
 
Page 12  
 
Revision 1.3 
software. Refer to the user’s manual of the particular product that will be used for configuring 
the TLM100 as these manuals provide detailed instruction on configuration procedures. 
 
3.4  Tank Depth or Custom Calibration 
The TLM100 can be easily programmed for use with tanks of rectangular cross-section (see 
Section  3.4.1). For non-rectangular tank shapes, you can perform custom calibration so that 
the TLM100 accurately reflects fluid levels (see Section 3.4.2).  
 
3.4.1  Tank Depth Programming 
The TLM100 can be used with tanks that have rectangular cross sections. The TLM100 comes 
from the factory programmed for a 40” (1.02m) deep tank. In order to obtain correct level 
readings on a tank having a rectangular cross section but shallower than 40” (1.02m), you 
must program the TLM100 with the actual depth of the tank using a display product such as 
the Maretron DSM250 or Maretron N2KAnalyzer software. Refer to the user’s manual of the 
particular product that will be used for configuring the TLM100 as these manuals provide 
detailed instruction on configuration procedures. 
 
3.4.2  Custom Calibration 
For accurate tank level readings, the TLM100 must be custom calibrated if the tank shape is 
irregular or non-rectangular. 
 
You can calibrate the TLM100 using a display product such as the Maretron DSM250 or 
Maretron N2KAnalyzer software. Refer to the user’s manual of the particular product that will 
be used for configuring the TLM100 as these manuals provide detailed instruction on 
configuration procedures. 
 
4  Maintenance 
Regular maintenance is not required; however, an occasional inspection will ensure continued 
proper operation of the Maretron TLM100. Perform the following tasks periodically: 
 
•  Clean the unit with a soft cloth.  Do not use chemical cleaners as they may remove 
paint or markings or may corrode the TLM100 enclosure or seals. Do not use any 
cleaners containing acetone, as they will deteriorate the plastic enclosure. 
•  Ensure that the unit is mounted securely and cannot be moved relative to the mounting 
surface.  If the unit is loose, tighten the screws holding the cable ties. 
•  Check the security of the cable connected to the NMEA 2000
®
 interface and tighten if 
necessary. 
 
5  Troubleshooting 
If you notice unexpected operation of the Maretron TLM100, follow the troubleshooting 
procedures in this section to remedy simple problems.