Maretron TLM100 用户手册

下载
页码 21
 
TLM100 User’s Manual  
 
 
 
 
 
Page 14  
 
Revision 1.3 
6  Technical Specifications 
Specifications 
Parameter 
Value 
Comment 
Accuracy ±2% 
 
Resolution ±1% 
 
Number of Tank Types 
16 
Fuel, Fresh Water, Waste Water, Live Well, Oil, etc. 
Number of Tanks per Tank Type 
16 
16 Tanks per Tank Type Numbered 0-15 
Maximum Tank Depth 
40” (1.02m)   
Minimum Depth Reading 
2” (5.08cm)  Sensor Deadband 
Support for Irregularly Shaped 
Tanks 
Yes 
Can be Calibrated for any Shape Tank 
Programmable Tank Capacity 
Yes 
Allows Displays to Calculate Amount Remaining 
Maximum Tank Angle 
6° 
Without focus tube 
15° 
With focus tube 
 
Certifications 
Parameter 
Comment 
NMEA 2000 
Level B+ 
Maritime Navigation and Radiocommunication Equipment & Systems 
Tested to IEC 60945 
FCC and CE Mark 
Electromagnetic Compatibility 
 
NMEA 2000
®
 Parameter Group Numbers (PGNs) - See Appendix A for Details 
Description 
PGN # 
PGN Name 
Default Rate 
Periodic Data PGNs 
127505 
Fluid Level 
0.4 Times/Second
Response to Requested PGNs 
126464 
PGN List (Transmit and Receive) 
N/A 
126996 Product 
Information 
N/A 
126998 Configuration 
Information 
N/A 
Protocol PGNs 
059392 
ISO Acknowledge 
N/A 
059904 ISO 
Request 
N/A 
060928 ISO 
Address 
Claim 
N/A 
065240 ISO 
Address 
Command 
N/A 
126208 NMEA 
N/A 
 
Electrical 
Parameter 
Value 
Comment 
Operating Voltage 
9 to 16 Volts 
DC Voltage 
Power Consumption 
<100mA 
Average Current Drain 
Load Equivalence Number (LEN) 
NMEA 2000
®
 Spec. (1LEN = 50mA) 
Reverse Battery Protection 
Yes 
Indefinitely 
Load Dump Protection 
Yes 
Energy Rated per SAE J1113