Reference Station
)
Connect the device to transmit real-time data to port P1, P2 or P3 of the receiver. 
Some devices fit into a clip-on-housing that plugs directly into these ports. Other 
devices require an interface cable. 
)
Unauthorised radio units should not be connected to the GRX1200 Series.
Cable connection
Cable connections are identical to other GPS1200 receivers. Additional cables are 
available from Leica Geosystems for the specific oscillator and Ethernet ports on the 
GRX1200 Pro.
Switch on
Hold down the ON/OFF button on the receiver for at least 2 s.
OR
OR
Send a pulse/data to one of the serial ports. Port P1, P2 and P3 can be config-
ured not to allow receiver switch on upon pulse reception.
Switch off
Press the ON/OFF button on the receiver for at least 4 s.