Husqvarna Portable Generator PP 418 用户手册

下载
页码 20
11
CONTROLS - OPERATION
 
Choke Lever
Ignition Switch
Flow Selector
Throttle Control
 
 
 
IGNITION SWITCH
STOP – Kills the engine – no power to any of the 
electrical devices.  
RUN – Run position for the engine.  Please note that the hour 
meter will collect time whether or not the engine is running.  If 
the key is left in the RUN position the battery will also loose 
power more quickly.
START – Turns the engine starter motor.
THROTTLE CONTROL
The engine has a very accurate electronic throttle and 
governing system.  The engine speed is strictly controlled 
electronically and you cannot make any simple mechanical 
adjustments to the governing system.   The electronic control 
will accurately hold the speeds as indicated below.
The throttle control switch allows you to select one of two 
different operating throttle control modes:
1. Automatic throttle control switch in the OFF position.
   - During the starting procedure the engine will run at
     2100 RPM for 5 seconds.
   - After 5 seconds the engine speed will increase to 
     3100 RPM and hold that speed.
2. Automatic throttle control switch in the ON position.
   - During the starting procedure the engine will run at 2100
     RPM for 5 seconds.
   - After 5 seconds the idle speed will drop to 1900 RPM.
   - When the trigger on a tool is activated a pressure 
     sensor switch on the power pack will increase the 
     engine speed to 3100 RPM.
   - When the tool is no longer used the engine speed will
     drop back to 1900 RPM after 5 seconds.
cont..
There is a slight delay for the engine to go from idle speed to 
full throttle operation.  To help prevent this inconvenience, the 
full throttle position is maintained for 5 seconds.  This is 
particularly helpful when a tool is operated intermittently 
(Hydraulic Breaker for example) and full power is required 
instantly.
If desired, full throttle operation can be maintained by moving 
the Automatic throttle control switch to the OFF position.
The sensitivity of the automatic throttle control system can 
be adjusted to compensate for conditions such as increased 
back pressure from adding hose extensions, operation at lower 
temperatures, oil viscosity differences, etc. 
 
Please see “ADJUSTING THE AUTOMATIC THROTTLE” on 
page 13.
FLOW SELECTOR
To adjust the oil fl ow PULL out on the fl ow selector knob and 
move it to the left for the desired oil fl ow.  Please consult the 
operator’s manual for fl ow requirements of a specifi c tool.  
Do not use a higher than recommend setting since that can 
damage the tool.
After the work is fi nished ALWAYS return the fl ow selector to 
“0” before stopping the engine.  
Always start the engine with the fl ow selector in the “0” 
position.  
This ensures that the electric starter can turn over 
the engine. 
This power pack is capable of producing up to 40 liter/ 10 gal 
of oil fl ow per min.  The factory pressure relief valve setting is 
148bar (2150psi) “cracking” pressure.