Tiered Configurations 
 
138
 
 
 
2.  Recycle the power of all impacted devices. This is recommended to 
build a clean database for Paragon switches. Sequence of recycling 
power is from the HIGHEST tier (third tier) to the Base Unit. In our 
example: UMT‐3A Æ UMT‐2A Æ UMT‐2B Æ UMT‐2C Æ UMT‐ 1A 
Æ UMT‐1B. 
Example B: Relocating a second‐tier device with multiple base connections (refer 
to blue line in the diagram
): 
1.  Disconnect some or all of the user ports on a tiered device (UMT‐2C) 
that connect to the channel ports of a Base Unit (UMT‐1A) and 
re‐connect those user ports to another Base Unit (UMT‐1B). 
2.  Recycle the power of impacted devices. This is recommended to 
build a clean database for Paragon switches. Sequence of recycling 
power is from the HIGHEST tier (second tier) to the Base Unit. In our 
example: UMT‐2C Æ UMT‐1A Æ UMT‐1B. 
The operation is the same for tiered devices that are not Paragon 
switches. 
 
Red color 
Example A 
Blue color 
Example B