Raritan Computer Paragon II 255-30-6000-00 用户手册
Chapter 2: Installation
25
3. Perform initial configuration of the user station.
a. The Login screen should appear on the user station’s attached
monitor. If the Scroll Lock LED on the user station’s attached
keyboard is blinking, the Paragon is ready to accept function key
commands, which allow users to login, select servers, or
administer the system.
keyboard is blinking, the Paragon is ready to accept function key
commands, which allow users to login, select servers, or
administer the system.
If the monitor instead displays a “.....No connection to
Paragon.....” message, the user station is not properly connected
to the Paragon switch. Check for loose connections and make sure
you are using good, intact Cat 5 cables.
Paragon.....” message, the user station is not properly connected
to the Paragon switch. Check for loose connections and make sure
you are using good, intact Cat 5 cables.
b. Type
admin in the User Name field and press Enter. In the
Password field, type the default password
raritan (all
lowercase) and press Enter.
c. The OSUI’s Selection Menu appears, indicating that the user
station is correctly installed.
4. Repeat steps 2 and 3 for each user station you want to connect to the
Paragon switch.
5. Connect a CIM and the desired server.
a. Connect the cable strands of an appropriate CIM to the
appropriate ports on a server: