VI. Specifications 
Sample Parameters:  
Vapor only, oil and liquid free, 300 psig (2 MPa) Maximum 
 
Detected Compounds:  
R12, R134a, Air and unknown compounds 
 
Sensor Technologies:  
Non-Dispersive Infrared and Chemical Fuel Cell 
 
Refrigerant Sample Size:  
0.12 ounces (3.5 grams) per typical sample – weight of vapor loss 
 
Power (Standard):  
Powered by vehicle battery through clip-on adapter harness (10 to 14 VDC). 
 
Power (Optional): 
Powered by line power through plug-in wall adapter harness, 115 VAC unit (OPTIONAL) or 220 VAC unit (OPTIONAL) 
 
Operational Temperature Range:  
45-100
o
F (7-38
o
C) 
 
Instrument Weight:  
1.5 Lbs. (454 grams) 
 
R12/R134a Purity Setpoint:  
Pass if single refrigerant, R12 or R134a, is detected in concentrations equal to or greater than 98% by weight. 
 
Unknown Refrigerant Purity Setpoint:  
In the presence of detected unknown refrigerant types R12 or R134a is considered pure if detected in concentrations equal to or 
greater than 96% by weight. 
 
Effect of Air Concentrations:  
Air is not considered a contaminate and will be removed from the weight concentration determination of refrigerants. Air 
concentrations will only be reported for blends of R12 and R134a refrigerants. 
SAE J1771: 
If the refrigerant being tested is identified as contaminated, any visual percentages displayed of CFC-12 (R-12) or HFC-134a (R-
134a) outside the design certified value is informational and may not be accurate. SAE J1771 Certification Note: This equipment 
has not been designed certified for contaminate detection of R-124 or R-142B.