National Instruments Power Supply shuttle NI PXIe-1062Q 用户手册

下载
页码 8
NI PXIe-1062Q Power Supply Shuttle User Guide
4
ni.com
Caution
Never connect the AC power cable to the power supply shuttle until you install it 
in a NI PXIe-1062Q chassis. Do not use, test, or configure the power supply shuttle outside 
of a chassis.
The power supply shuttle is a replacement part for the NI PXIe-1062Q 
chassis. The NI PXIe-1062Q User Manual contains all of the most 
up-to-date chassis service procedures, including removal and replacement 
of power supply shuttles. The chassis includes a hardcopy of the 
NI PXIe-1062Q User Manual; additionally, you can download a softcopy 
from 
ni.com/support
.
Removal
Before attempting to replace the power supply shuttle, verify that there is 
adequate clearance behind the chassis. With the chassis powered off, 
disconnect the power cable from the power supply shuttle on the back of 
the chassis. Identify the eight mounting screws that attach the power supply 
shuttle to the chassis. Refer to Figure 1 for the mounting screw locations. 
Using a Phillips screwdriver, remove the mounting screws. Pull on the 
two rear handles of the power supply shuttle to remove it from the back of 
the chassis.
Installation
Ensure that there is no visible damage to the new power supply shuttle. 
Verify that the housing and connector on the new power supply shuttle 
have no foreign material inside. Remove the protective cap on the 
PXI_CLK10 connector. Install the new power supply shuttle into the 
opening on the rear of the chassis. Install and tighten the eight mounting 
screws with a Phillips screwdriver.
Configuration
The fan-speed selector switch is on the rear panel of the power supply 
shuttle. Refer to Figure 1 to locate the fan-speed selector. Select HIGH for 
maximum cooling performance (recommended) or AUTO for quieter 
operation. When set to AUTO, air-intake temperature determines the fan 
speed.