Maretron ACM100 用户手册

下载
页码 24
 
ACM100 User’s Manual  
 
 
 
 
Page 16 
 
 
Revision 1.2 
 
Electrical 
Parameter 
Value 
Comment 
Sensed Voltage 
0-240 VAC 
120,120/240,240,208Y,380Y configurations 
Sensed Current 
0-200 A 
With supplied current transformer 
Operating Voltage 
5 to 36 Volts 
DC Voltage 
Power Consumption 
100 mA 
NMEA 2000
®
 Interface 
Load Equivalence Number (LEN) 
NMEA 2000
®
 Spec. (1LEN = 50 mA) 
Reverse Battery Protection 
Yes 
Indefinitely 
Load Dump Protection 
Yes 
Energy Rated per SAE J1113 
 
Mechanical 
Parameter 
Value 
Comment 
Size 
3.50” x 4.20” x 2.03” 
(88.9mm x 106.7mm x 51.6mm) 
Including Flanges for Mounting 
Weight 
13 oz. (368.5 g) 
 
 
Environmental 
Parameter 
Value 
IEC 60954 Classification 
Exposed 
Degree of Protection 
IP64 
Operating Temperature 
-25°C to 55°C 
Storage Temperature 
-40°C to 70°C 
Relative Humidity 
93%RH @40° per IEC60945-8.2 
Vibration 
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 
Solar Radiation 
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 
Corrosion (Salt Mist) 
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 
Electromagnetic Emission 
Conducted and Radiated Emission per IEC 60945-9 
Electromagnetic Immunity 
Conducted, Radiated, Supply, and ESD per IEC 60945-10 
Safety Precautions 
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 
 
 