Amana PTH094G35AXXX 目录

下载
页码 20
9
Specifications and Accessories Catalog
* Actual vent CFM performance will vary due to application and installation conditions.
Notes
¹  Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.  
2  Minimum voltage on 115-volt models is 109 volts; maximum is 127 volts.
3  Overcurrent protection for all units without electric heaters is 15 amps.
⁴  R-410A refrigerant used in all systems.
⁵  All units meet or exceed ASHRAE 90.1 standards.
⁶  All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
Model 5
,
 6
PTC 
072G**XXX
PTC 
092G**XXX
Voltage 2
115
115
Capacity (BTU/h)
7000
9000
Amps
6.9
8.3
Watts
585
795
EER
11.9
11.3
Min. Circuit Amps 1
,
 3 
8.3
10.1
CFM (Cool/Wet Coil)
High
290
290
Low
264
264
CFM (Dry Coil)
High
310
310
Low
282
282
Ventilated Air, (Fan Only)*
65*
65*
Dehumidification (Pints/Hr.)
1.7
2.3
Net Weight (lbs.)
98
102
Ship Weight (lbs.)
113
117
Product Specifications:  PTC 115-Volt Models —  
Cooling/Hydronic Heat or No-Heat Models