9
Install Range Hood
1. Remove the grease filters. See the “Range Hood Care” 
section.
2. Remove mounting screws and lateral supports.
3. For vented installations:
Depending on your installation, remove either top or rear 
rectangular vent knockout. If using round vent, remove 
top rectangular knockout.
NOTE: Do not remove rectangular knockouts if 
installation of range hood is to be non-venting 
(recirculating).
Make sure damper pivot is nearest to top/back edge of 
range hood. 
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed up 
to 1" (2.5 cm) on either side of the hood center to 
accommodate off-center ductwork.
If using rectangular vent, attach rectangular damper/vent 
connectors to the range hood using sheet metal screws.
If using round vent, attach vent transition piece 
(purchased separately) to range hood top using sheet 
metal screws.
NOTE: If the wall cap is directly behind the vent 
connector, the dampers in the connector and wall cap 
must not interfere with each other. Remove the vent 
connector damper if they interfere.
4. Lift the range hood up under cabinet and determine final 
location by centering beneath cabinet. Mark on the underside 
of cabinet the location of the 4 keyhole mounting slots on the 
range hood. Set range hood aside on a covered surface.
5. Use 
¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
6. Install the 4 - #10 x 
⁵⁄₈" mounting screws in pilot holes. Leave 
about 
¹⁄₄" (6.4 cm) space between screw heads and cabinet 
to slide range hood into place.
A. Lateral supports
B. Mounting screws
A
A
B
A. Vertical vent
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Horizontal vent
A. Keyhole slot
A. Drill pilot hole
A
B
C
D
C
B
E
A
A
¹⁄₄
"
(6.4 mm)