5. Mark Hole Locations 
Lift the range hood into place and insert the mounting bracket 
tabs through the slots in the back of the range hood. 
Hold the range hood firmly in place with one hand and bend each 
mounting tab (A) upward approximately 90°.
Mark the hole at the power supply knockout (B).
For a top vented installation: Mark the 4 vent hole locations (C) 
on the top of the range hood.
For a rear vented installation: Mark the 4 vent hole locations (D) 
on the rear of the range hood.
OPTIONAL: Mark the hole in each mounting tab.
Remove the range hood and set it aside.
6. Mark and Cut Vent Opening 
3
¹⁄₄" x 10" (8.3 x 25.4 cm) Rectangular Vent System
Using a 
¹⁄₂" (13 mm) drill bit, drill a hole in each of the dots 
marked previously on either the wall or upper cabinet. Using 
the outside edges of the holes, mark the vent opening.
Using a jigsaw or keyhole saw, cut the vent opening.
7. Drill Electrical Opening
Using a 1
¹⁄₄" (3 cm) drill bit, drill the hole in the dot marked 
previously at the electrical strain relief.
OPTIONAL: Using a 
¹⁄₈" (3 mm) drill bit, drill pilot holes for the 
dots marked previously at each mounting tab at an approximate 
45° angle in an upward direction.
45˚+
A
B
C
C
D
D
A
90˚