GE DSKS433EBWW 规格说明表单

下载
页码 4
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
360432
Specification Revised 5/09
Listed by 
Underwriters 
Laboratories
DSKS433EB 
GE Spacemaker
® 
Stationary Dryer
Dimensions and Installation Information (in inches) 
Special Installation Requirements
Alcove or Closet Installation:
 
•  If your dryer is approved for installation in an alcove or closet, it will be stated on 
a label on the dryer back.
• The dryer MUST be exhausted to the outside. 
•  Minimum clearances between dryer cabinet and adjacent walls or other 
surfaces are: 
    0" either side 
       3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. 
•  Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains 
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open 
area equally distributed.
•  No other fuel-burning appliance shall be installed in the same closet with  
a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. 
•  The installation must conform with the local codes, or in the absence of local 
codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 
for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
•  Minimum clearances to combustible surfaces 
    0" both sides
       3" rear
Best performance
Domestic  
dryer models
Maximum length of 4"
dia. 
rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4" 
opening
B
2-1/2" 
opening
DSKS433EB
DSKS333EC
DSKP333EC
WSM2780H
3
46 ft.
38 ft.
31 ft.
24 ft.
37 ft.
30 ft.
22 ft.
15 ft.
WSM2700H
3
56 ft.
46 ft.
34 ft.
32 ft.
42 ft.
36 ft.
28 ft.
18 ft.
WSM2420D
WSM2480D
2
43 ft.
33 ft.
23 ft.
36 ft.
26 ft.
16 ft.
A
4
B
2-1/2