DSKS433EB 
GE Spacemaker
® 
Stationary Dryer
Dimensions and Installation Information (in inches) 
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
 
For best performance, this dryer should be vented with 4" diameter all rigid metal 
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) 
ducting can be used (Kit WX08X10077). In special installations, it may be necessary to 
connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed 
flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or 
flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter can be 
maintained throughout the entire length of the transition duct. Please see installation 
instruction packed with your dryer for complete instructions when using flexible metal 
(foil type) ducting. 
Exhaust Length Calculation: 
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the 
side or bottom of dryer, add one turn.
2.  The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated 
is shown in the table. 
   A turn of 45° or less may be ignored. Two 45° turns within the duct length should be 
treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers 
must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any 
enclosed house floor (crawl space), or into an attic, since the accumulated lint could 
create a fire hazard or moisture could cause damage. Never terminate the exhaust into 
a common duct or plenum with a kitchen exhaust, since the combination of lint and 
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird 
nesting, etc. The wall cap must also be located at least 12" above the ground or any 
other obstruction with the opening pointed down.
Dryer Note: Dryer wall outlet must be located within 36" of service 
cord entry and accessible when dryer is mounted in position.
DSKS433EBWW
80
100
10
90
OFF
OFF
60
50
40
30
20
70
PERM. PRESS & DEL
ICATES CYCLE
T I M E D   CYC L E
PUSH TO START
AU TO
R EG U L A R
  TEMPERATURE
REGULAR
(HIGH HEAT)
PERM PRESS
(MED. HEAT)
DELICATES
(LOW HEAT)
FLUFF
(NO HEAT)
*
OFF
cool down
cool
down
*
33-1/4
24-1/2
23-7/8