Capital MWOV302ES 安装指导

下载
页码 16
 
- 9 - 
UNPACKING AND HANDLING 
1.  Move the oven as close to the point of installation as possible prior to removing packing materials to 
prevent damage. 
2.  Remove all packing materials from inside the oven and any protective plastic on the outside of the oven. 
3.  Read and retain all instructions before installation and use and after installation as a reference. 
4.  The units are heavy. Plan sufficient manpower and use caution when lifting the unit. 
 
ELECTRICAL WIRING INSTALLATION: 
WARNING: 
1.  All wiring must comply with all local ordinances and building codes. 
2.  Electrical services at the installation must meet or exceed those specified for the appliance. Do not 
proceed with the installation until the specifications are met. Call a licensed electrician, if required, to 
meet the necessary requirements.  
3.  To prevent electric shock or fire hazard, turn off power at the circuit breaker or fuse box prior to 
connecting the oven. 
4.  Improper connection of the electrical wiring can cause an electric shock hazard and damage the 
appliance. Capital Cooking Equipment is not responsible for damages resulting from improper installation. 
5.  The ground wire of the oven must be connected to a grounded metallic, permanent wiring system or 
grounding conductor. 
6.  Do not use an extension cord with this appliance. Fire, electric shock or other personal injury or damage 
may occur as a result. 
7.  Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an 
electric shock hazard. 
8.  Use copper wire only when connecting the oven to the circuit breaker or fuse. 
9.  Flexible armored or non-metallic, sheathed copper cable (with grounding wire) should be used to connect 
the appliance to the circuit breaker or junction box. A UL listed connector must be used if directly 
connecting the wiring to the junction box. 
IMPORTANT:  Prior to installation and preparation of the wiring, power to the planned oven electrical circuit must 
be turned off at the breaker or fuse box. 
STANDARD WIRING (FOUR WIRE CONNECTION) 
1.  Each wire must be individually connected to the household supply wire. 
2.  Connect the Green appliance ground wire to the Green household ground wire from the junction box. 
3.  Connect the appliance Black L1 wire to the household Black L1 wire from the junction box. 
4.  Connect the appliance White Neutral wire to the household White neutral wire from the junction box. 
5.  Connect the appliance Red L2 wire to the household Red L2 wire from the junction box. 
DEVIATIONS FROM STANDARD WIRING (MUST COMPLY WITH LOCAL CODES)
1.  Three Wire Connection – Must be permitted by local codes 
a.  Each wire must be individually connected to the household supply wire. 
b.  Connect the appliance Black L1 wire to the household Black L1 wire from the junction box. 
c.  Connect the appliance White Neutral wire and the Green appliance wire to the household White 
neutral wire from the junction box.