Whirlpool WOC97ES0ES 安装指导

下载
页码 16
4
Electrical Connection
To properly install your oven, you must determine the type 
of electrical connection you will be using and follow the 
instructions provided for it here.
 
Oven must be connected to the proper electrical voltage, 
amperage, and frequency as specified on the model/serial/ 
rating plate. See the following illustration.
A
A. Model/serial/rating plate
 
Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to  
7.4 kW at 208 volts) require a separate 40-amp circuit. 
Models rated at 4.8 kW and below at 240 volts (3.6 kW  
and below at 208 volts) require a separate 30-amp circuit.
 
A circuit breaker is recommended.
 
Connect directly to the fused disconnect (or circuit breaker 
box) through flexible, armored or nonmetallic sheathed, 
copper cable (with grounding wire). See “Make Electrical 
Connection” section.
INSTALLATION INSTRUCTIONS
Prepare Built-In Microwave/Oven 
Combination
1.   Decide on the final location for the oven. Locate existing  
wiring to avoid drilling into or severing wiring during  
installation.
2.   To avoid floor damage, set the oven onto cardboard prior 
to installation. Do not use handle or any portion of the front 
frame for lifting.
3.   Remember to remove bottom vent from the foam packing  
on top of oven.
4.  Remove the shipping materials and tape from the oven.
5.   Remove the hardware package from inside the bag  
containing literature.
6.   Remove and set aside racks and other parts from inside  
the oven.
7.   Move oven and cardboard close to the oven’s final location.
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
Remove Oven Door(s)
IMPORTANT: Use two hands to remove oven door.
1.   Prior to removing the oven door, prepare a surface where 
you will place it. This surface should be flat and covered with 
a soft blanket, or use the corner posts from your packaging 
material.
2.  Open the oven door.
3.   Locate the oven door hinge locks in both corners of the 
oven door, and then rotate the hinge locks toward the oven 
door to the unlocked position. If the door hinge lock is not 
rotated fully (see illustration B), the door will not remove 
properly.
B
A
A.  Oven door hinge lock  
in locked position
B.  Oven door hinge lock  
in unlocked position
Flexible conduit from the oven should be connected           
 
directly to the junction box.
 
Do not cut the conduit. The length of conduit provided         
is for serviceability of the oven.
 
A UL-listed or CSA-approved conduit connector must be 
provided.
 
If the house has aluminum wiring, follow the procedure 
below:
1.  Connect a section of solid copper wire to the ends 
of the flexible conduit leads.
2.  Connect the aluminum wiring to the added section  
of copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s  
recommended procedure. Aluminum/copper connection 
must conform with local codes and industry-accepted  
wiring practices.
For power requirements, refer to the following table:
Voltage
Amperage
Amperage
Rating
(L1)*
(L2)*
(W)
120/240
32
30
8.0 kW
120/208
30
28
6.6 kW
Amperage values noted above are for information purposes  
only: The units are rated in watts. 
*