22       User's Guide
15.  Grasping the Sensor Adjust Knob and sliding in or out as needed can move the Media
Sensor.  This is required only if the sensor must be moved to a specific location on the
label to detect a notch (hole) or gap.
Figure 16 - Media Sensor Adjust Knob
16.  Important: To ensure proper media feeding and sensor operation, complete the following
checklist:
Media is wound Face Out (print side out) and feeding off the top of the roll.
Media is routed exactly as shown  over the  Back Media Rail and  under  the
Front Media Rail
.
Media is routed between the Upper and  Lower Media Sensor Arms located
under print module.
The green Outside Media Guide  has been re-installed.
If required, the media sensor is adjusted directly over the notch (hole) or gap.