Input from exit loop provides signal for optional LiftMaster loop 
SENSE 
detector add-on board.  Operation is the same as Exit Loop input, 
above. 
RADIO INPUT (TB6) 
RADIO RECV 
Convenience terminals provide power and contact connection for a radio 
receiver.  Activation is the same as CYCLE. 
OBSTRUCTION ALARM (TB17) 
Relay contacts close to provide 24DC alarm power if the gate has two 
consecutive obstruction faults. 
LOW BATTERY/ NO AC POWER (TB18) 
LOW BATTERY  Activation fully opens or closes the gate, depending the setting of Switch 
S3.  
NO AC POWER  Activation registers the date and time of power outages in the gate 
operator transaction buffer. 
24VAC OUTPUT (TB7)  Terminals provide power (24VAC, 200mA) for peripheral devices. 
MAGLOCK INPUT (TB4) 
MAGLOCK 
Relay contacts close when the gate is fully closed. 
MASTER/SLAVE I/O INPUT (TB1) 
MASTER/SLAVE I/O  Input/output terminals are used to control a second gate operator in 
a Master/Slave system. 
 
PHONE LINE (J9) 
Terminals connect the telephone line to the gate operator.