ADJUSTMENTS 
OBSTRUCTION 
Adjustable pot controls gate sensitivity to blockages by the 
RIGHT (R69) 
instantaneous rise in motor current.  When the limit is exceeded, the 
gate stops and reverses a programmed distance (a minimum of 2 
inches). 
 
OBSTRUCTION 
Adjustable pot controls gate sensitivity to blockages by the 
LEFT (R160)   
instantaneous rise in motor current.  When the limit is exceeded, the 
gate stops and reverses a programmed distance (a minimum of 2 
inches). 
NOTE: LiftMaster gate operators have two obstruction sense adjustments (left and 
right) where other gate operators have only one.  This allows greater 
flexibility of installation.  For instance, you can install a gate on an incline 
and not worry about sacrificing downhill gate sensitivity. 
INRUSH  
Adjustable pot controls the delay in sensitivity to gate 
(R203) 
obstructions.  This delay in sensitivity prevents the initial motor 
inrush current from causing a obstruction fault.  The weight of the 
gate determines this setting. 
CONNECTORS 
LIMIT SWITCH (J4) 
Connector for the left/right limit switch cable. 
PWR INPUT (J1) 
Connector for AC input power. 
MOTOR POWER (J3)  Connector for the motor cable. 
LOOP DETECTOR 
Connector for the optional LiftMaster Outside Interrupt Loop 
detector 
(J15) add-on 
board. 
LOOP DETECTOR 
Connector for the optional LiftMaster Inside Interrupt Loop detector 
(J12) add-on 
board. 
LOOP DETECTOR 
Connector for optional LiftMaster Shadow Loop detector add-on 
(J13) board. 
LOOP DETECTOR 
Connector for optional LiftMaster Exit Loop detector add-on board. 
(J14) 
OBSTRUCTION 
Connector for factory-installed alarm. 
ALARM