Silverstone SST-ST30NF-V4.1 用户手册
3.3 Dynamic Loading
The output voltages shall remain within the limits specified in Table 7 for the step loading
and within the limits specified in Table 8 for the capacitive loading. The load transient
repetition rate shall be tested between 50Hz and 5 kHz at duty cycle ranging from 10%-90%.
The load transient repetition rate is only a test specification.
The (a)step load may occur anywhere within the MIN load to the MAX load shown in Table
5 and Table 6.
The output voltages shall remain within the limits specified in Table 7 for the step loading
and within the limits specified in Table 8 for the capacitive loading. The load transient
repetition rate shall be tested between 50Hz and 5 kHz at duty cycle ranging from 10%-90%.
The load transient repetition rate is only a test specification.
The (a)step load may occur anywhere within the MIN load to the MAX load shown in Table
5 and Table 6.
Output
(a)step Load Size
Load Slew Rate
Capacitive Load
+5V
30% of Max. Load
0.5 A/uS
1000 uF
+3.3V
30% of Max. Load
0.5 A/uS
1000 uF
+12V
30% of Max. Load
0.5 A/uS
2200 uF
+5VSB
30% of Max. Load
0.5 A/uS
1 uF
Table 8 – Transient Load requirements
3.4 Capacitive Loading
The power supply shall be stable and meet all requirements, except dynamic loading
requirements, with the following capacitive loading ranges.
Output MIN MAX Units
+5V 10
12,000
uF
+3.3V 10 12,000 uF
+12V 10 11,000 uF
-12V 1 350 uF
+5VSB 1 350 uF
Table 9 – Capacitive Loading Conditions
3.5 Timing Requirements
These are the timing requirements for the power assembly operation. The output voltages
must rise from 10% to within regulation limits (T
vout_rise
) within 5 to 200mS. The +5V, +3.3V
and +12V output voltages should start to rise at about the same time. All outputs must rise
monotonically. The +5V output needs to be greater than the +3.3V output during any point
of the voltage rise. The +5V output must never be greater than the +3.3V output by more than
2.25V. Each output voltage shall reach regulation within 50 mS (T
monotonically. The +5V output needs to be greater than the +3.3V output during any point
of the voltage rise. The +5V output must never be greater than the +3.3V output by more than
2.25V. Each output voltage shall reach regulation within 50 mS (T
vout_on
) of each other
during turn on of the power supply. Each output voltage shall fall out of regulation within
400 mS (T
400 mS (T
vout_off
) of each other during turn off.
Item Description
MIN
MAX
Units
Tvout_rise
Output voltage rise time from each main output
5
70
mS
Tvout_on
All main output must be within regulation of each
other within this time.
other within this time.
50
mS
Tvout_off
All main output must leave regulation within this
time
time
400
mS
Table 10 – Output Voltage Timing