Silverstone SST-ST30NF-V4.1 用户手册

下载
页码 10
3.3 Dynamic Loading 
The output voltages shall remain within the limits specified in Table 7 for the step loading 
and within the limits specified in Table 8 for the capacitive loading. The load transient 
repetition rate shall be tested between 50Hz and 5 kHz at duty cycle ranging from 10%-90%. 
The load transient repetition rate is only a test specification. 
The (a)step load may occur anywhere within the MIN load to the MAX load shown in Table 
5 and Table 6. 
 
Output 
(a)step Load Size 
Load Slew Rate 
Capacitive Load 
+5V 
30% of Max. Load 
0.5 A/uS 
1000 uF 
+3.3V 
30% of Max. Load 
0.5 A/uS 
1000 uF 
+12V 
30% of Max. Load 
0.5 A/uS 
2200 uF 
+5VSB 
30% of Max. Load 
0.5 A/uS 
1 uF 
Table 8 – Transient Load requirements 
 
3.4 Capacitive Loading 
The power supply shall be stable and meet all requirements, except dynamic loading 
requirements, with the following capacitive loading ranges. 
 
Output MIN  MAX  Units 
+5V 10 
12,000 
uF 
+3.3V 10 12,000 uF 
+12V 10 11,000 uF 
-12V 1  350 uF 
+5VSB 1  350  uF 
Table 9 – Capacitive Loading Conditions 
 
3.5 Timing Requirements 
These are the timing requirements for the power assembly operation. The output voltages 
must rise from 10% to within regulation limits (T
vout_rise
) within 5 to 200mS. The +5V, +3.3V 
and +12V output voltages should start to rise at about the same time. All outputs must rise 
monotonically.    The +5V output needs to be greater than the +3.3V output during any point 
of the voltage rise. The +5V output must never be greater than the +3.3V output by more than 
2.25V. Each output voltage shall reach regulation within 50 mS (T
vout_on
) of each other 
during turn on of the power supply. Each output voltage shall fall out of regulation within 
400 mS (T
vout_off
) of each other during turn off. 
 
Item Description 
MIN 
MAX 
Units 
Tvout_rise 
Output voltage rise time from each main output 
70 
mS 
Tvout_on 
All main output must be within regulation of each 
other within this time. 
 50 
mS 
Tvout_off 
All main output must leave regulation within this 
time 
 400 
mS 
Table 10 – Output Voltage Timing