3.6 Power Good Signal: PWOK 
PSOK is a power OK signal and will be pulled HIGH by the power supply to indicate that all 
the outputs are within the regulation limits of the power supply. When any output voltage 
falls below regulation limits or when AC power has been removed for a time sufficiently 
long so that power supply operation is no longer guaranteed, PWOK will be deasserted to a 
LOW state. See for a representation of the timing characteristics of PWOK. The start of 
PWOK delay time shall inhibited as long as any power supply output is in current limit. 
 
Signal Type 
Open collector/drain output from power supply.   
Pull-up to VSB located in power supply 
PWOK = High 
Power OK 
PWOK = Low 
Power is not OK 
 MIN 
MAX 
Logic level low voltage, Isink = 4mA 
0V 
0.4V 
Logic level high voltage, Isource = 200μA 
2.4V 5.25V 
Sink current, PWOK = Low 
 
4mA 
Source current, PWOK = High 
 
2mA 
PWOK delay: Tpwok_on 
100mSec 
1000mSec 
PWOK rise and fall time 
 
100μSec 
Table 12 – PWOK Signal Characteristics 
 
3.7 Remote On/Off Control : PSON# 
The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active 
low signal that turns on the +5V, +3.3V, +12V and –12V power rails. When this signal is not 
pulled low by the system, or left open, the outputs(except the +5VSB and Vbias) turn off. 
This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. 
Signal Type 
Accepts an open collector/drain input 
from the system.    Pull-up to VSB 
located in power supply. 
PSON# = Low 
Power ON 
PSON# = Open 
Power OFF 
 MIN 
MAX 
Logic level low (Power supply ON) 
0V 
0.8V 
Logic level low (Power supply OFF) 
2.0V 
5.25V 
Source current, Vpson = Low 
 
4mA 
Power up delay: Tpson_on_delay 
5mSec 
400mSec 
PWOK delay: Tpson_pwok 
 
50mSec 
Table 13 – PWOK Signal Characteristics 
 
3.8 Overshoot at Turn-on /Turn-off 
Any output overshoot at turn on shall be less than 10% of the nominal output value. Any 
overshoot shall recover to within regulation in less than 10ms. 
 
3.9 Efficiency 
The minimum power supply system efficiency shall be 
≥ 70%, measured at nominal input 
voltage 115 V or 230 V and full loading. 
 
3.10 +5VSB (Standby) 
The +5VSB output is always on (+5V Standby) when AC power is applied and power switch 
is turned 
on. The +5VSB line is capable of delivering at a maximum of 
1.5
A for PC board 
circuit to operate.