INSTALLATION
Continued
Figure 9 - Rough Opening for Installing 
in Corner 
Figure 8 - Rough Opening for Installing 
in Wall 
43
5
/
16
"
30
5
/
8
"
61
1
/
4
"  
26
7
/
8
"
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floor
Minimum
15 
1
/
4
"
   
Actual 
Framing
  Height 
26" 
26 
7
/
8
"
  Front Width 
26 
3
/
4
26 
7
/
8
"
  Depth 
14 
1
/
4
15 
1
/
4
"
1.  Frame in rough opening. Use dimensions shown 
in Figure 8 for the rough opening. If installing 
in a corner, use dimensions shown in Figure 
10 for the rough opening. The height is 26 
7
/
8
which is the same as the wall opening above.
2.  If installing GA3450TA blower accessory, do 
so at this time. Follow instructions included 
with blower accessory.
 
Note:
 If not installing blower accessory, you 
may  wish  to  run  electrical  wiring  to  your 
fireplace for future blower installation (see 
Accessories,  page  44).  Use  only  approved 
three-wire electrical wiring.
 WARNING: If pre-wiring, do 
not connect wiring to any electri-
cal source at this time.
Install fireplace electrical outlet 
and  connect  wiring  to  outlet 
before connecting to electrical 
source.  The  fireplace  electri-
cal  outlet  is  included  with  the 
GA3450TA blower accessory.
Only  use  the  fireplace  electri-
cal  outlet  supplied  with  the 
GA3450TA blower accessory.
Figure 10 - Attaching Fireplace to Wall Studs 
Nailing 
Flanges
Nails or 
Wood 
Screws
Wall Studs
Note:
 A qualified installer should make all electri-
cal connections.
3.  Install gas piping to fireplace location. This 
installation includes an approved flexible gas 
line (if allowed by local codes) after the equip-
ment shutoff valve. The flexible gas line must 
be the last item installed on the gas piping.
4.  If you have not installed hood, follow instruc-
tions on page 6.
5.  Carefully set fireplace in front of rough opening 
with back of fireplace inside wall opening.
6.  Attach flexible gas line to fireplace gas regula-
tor. See Connecting Equipment Shutoff Valve 
to Heater Control,
 page 17.
7.  Bend four nailing flanges on outer casing with 
pliers (see Figure 10).
8.  Attach fireplace to wall studs using nails or 
wood screws through holes in nailing flange.
9.  Check all gas connections for leaks. See Check-
ing Gas Connections
, page 17.
10.  If using optional brass trim kit, install the trim 
after final finishing and/or painting of wall. 
See instructions included with brass trim ac-
cessory for attaching brass trim.
IMPORTANT: 
When finishing your firebox, combus-
tible materials such as wall board, gypsum board, sheet 
rock, drywall, plywood, etc. may be butted up next to 
the sides and top edge of the firebox. Combustible ma-
terials should never overlap the firebox front facing. 
 WARNING: Do not allow any 
combustible/noncombustible 
materials to overlap the firebox 
front facing. 
  WARNING:  Do  not  allow 
noncombustible  materials  to 
cover any necessary openings 