3M 965AMS 用户手册
198
Self-Test Board
3M™ Dynatel™ Advanced Modular System 965AMS
Self-Test Board>Check RFL Performance
1. Connect the test leads as shown. Press the
key on the
965AMS tester.
3 965AMS
2. Press the
Setup
key, enter 70°F (21°C) for temperature.
3. Press the
OK
key to accept.
4. Select Separate Pair hookup, then continue. You should see
the following readings for different wire gauges (US and
Canada).
AWG
DTS
DTF
DSTF
Min
Max
Min
Max
Min
Max
19
11910
(3630)
(3630)
12290
(3747)
(3747)
1170
(357)
(357)
1230
(375)
(375)
10730
(3271)
(3271)
11070
(3375)
(3375)
22
5986
(1825)
6171
(1881)
592
(180)
613
(187)
5393
(1644)
5559
(1695)
24
3755
(1145)
3871
(1180)
371
(109)
385
(117)
3383
(1031)
3488
(1063)
25
2970
(905)
(905)
3063
(934)
(934)
293
(89)
(89)
305
(93)
(93)
2676
(816)
(816)
2759
(841)
(841)
26
2347
(716)
(716)
2420
(738)
(738)
232
(71)
(71)
240
(73)
(73)
2114
(645)
(645)
2180
(665)
(665)
28
1479
(451)
(451)
1526
(465)
(465)
146
(44)
(44)
152
(46)
(46)
1332
(406)
(406)
1375
(419)
(419)
Ohms
99.3
102.5
9.8
10.2
89.5
92.3