Silverstone SST-ST56F-V3.2 用户手册
2. DC OUTPUT
2.1 DC voltage regulation
Parameter
Range
Min
Nom.
Max
Unit
+3.3V
+/-5%
+3.14
+3.3
+3.47
Volts
+5V
+/-5%
+4.75
+5
+5.25
Volts
+12V1
+/-5%
+11.4
+12
+12.6
Volts
+12V2
+/-5%
+11.4
+12
+12.6
Volts
-12V
+/-10%
-10.8
-12
-13.2
Volts
+5VSB
+/-5%
+4.75
+5
+5.25
Volts
2.2 Load ranges
2.2.1 : (560 Watts Load Ratings)
Parameter
Min
Nom.
Max
Peak
Unit
+3.3V
+5V
+12V1
+12V2
+12V2
-12V
+5VSB
0.5
0.3
1.0
1.0
0.0
0.0
0.3
1.0
1.0
0.0
0.0
12.0
24.0
17.0
15.0
24.0
17.0
15.0
0.5
2.0
2.0
30.0
30.0
18.0
18.0
30.0
18.0
18.0
0.5
2.0
2.0
19.0
19.0
19.0
2.5
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Notes:
(1) The maximum continuous total DC outputs power shall not exceed 560W
(2) The maximum peak total DC output power shall not exceed 570W
(limited to duty cycle of 1 minute on, 10 minutes off at 40°C ambient).
(3) The maximum continuous load on +5V and +3.3V outputs shall not exceed 180W.
(4) The maximum combined current for the +12V outputs shall be 36A
(5) When +5V load is 28A, +12V (+12V1 and +12V2) minimum load is 2A
(6) When the combined current for the +12V outputs is 29A, the +5V minimum load is 5A.
(7) When the combined current for the +12V outputs is 22A, the +5V minimum load is 2A.
(2) The maximum peak total DC output power shall not exceed 570W
(limited to duty cycle of 1 minute on, 10 minutes off at 40°C ambient).
(3) The maximum continuous load on +5V and +3.3V outputs shall not exceed 180W.
(4) The maximum combined current for the +12V outputs shall be 36A
(5) When +5V load is 28A, +12V (+12V1 and +12V2) minimum load is 2A
(6) When the combined current for the +12V outputs is 29A, the +5V minimum load is 5A.
(7) When the combined current for the +12V outputs is 22A, the +5V minimum load is 2A.
2.3 Output Ripple
2.3.1 Ripple regulation
Parameter
Ripple&Noise
Unit
+3.3V
80
mVp-p
+5V
50
mVp-p
+12V1
120
mVp-p
+12V2
120
mVp-p
-12V
120
mVp-p
+5VSB
50
mVp-p