Silverstone SST-ST56F-V3.2 用户手册

下载
页码 8
2. DC OUTPUT 
 
2.1 DC voltage regulation 
Parameter  
Range  
Min  
Nom. 
Max  
Unit  
+3.3V  
+/-5%  
+3.14  
+3.3  
+3.47  
Volts  
+5V  
+/-5%  
+4.75  
+5  
+5.25  
Volts  
+12V1  
+/-5%  
+11.4  
+12  
+12.6  
Volts  
+12V2  
+/-5%  
+11.4  
+12  
+12.6  
Volts  
-12V  
+/-10%  
-10.8  
-12  
-13.2  
Volts  
+5VSB  
+/-5%  
+4.75  
+5  
+5.25  
Volts  
 
 
 
2.2 Load ranges 
2.2.1 : (560 Watts Load Ratings) 
Parameter 
Min 
Nom. 
Max 
Peak 
Unit 
+3.3V 
+5V 
+12V1 
+12V2 
-12V 
+5VSB 
0.5 
0.3 
1.0 
1.0 
0.0 
0.0 
12.0 
24.0 
17.0 
15.0 
0.5 
2.0 
30.0 
30.0 
18.0 
18.0 
0.5 
2.0 
 
19.0 
19.0 
 
2.5 
 
Amps 
Amps 
Amps 
Amps 
Amps 
Amps 
 
 
Notes:  
 
(1) The maximum continuous total DC outputs power shall not exceed 560W   
(2) The maximum peak total DC output power shall not exceed 570W 
      (limited to duty cycle of 1 minute on, 10 minutes off at 40°C ambient).   
(3) The maximum continuous load on +5V and +3.3V outputs shall not exceed 180W.   
(4) The maximum combined current for the +12V outputs shall be 36A 
(5) When +5V load is 28A, +12V (+12V1 and +12V2) minimum load is 2A 
(6) When the combined current for the +12V outputs is 29A, the +5V minimum load is 5A. 
(7) When the combined current for the +12V outputs is 22A, the +5V minimum load is 2A. 
 
 
   
2.3 Output Ripple   
2.3.1 Ripple regulation   
 
Parameter  
Ripple&Noise  
Unit 
+3.3V  
80  
mVp-p 
+5V  
50  
mVp-p 
+12V1  
120  
mVp-p 
+12V2  
120  
mVp-p 
-12V  
120  
mVp-p 
+5VSB  
50  
mVp-p