Beckett SLD4100 用户手册

下载
页码 32
 
Ratings and Data 
 
 
 
 
 
 
 
 
 
 
Boiler 
Model 
No. 
SL375  SLD375  SL4100 SLD4100 SL5125 SLD5125 SL6150  SL7175 
Firing Rate - #2 Fuel 
0.75 
0.75 
1.00
1.00
1.25
1.25 
1.50
1.75
Input 
BTU/HR 
105,000 105,000 140,000
140,000
175,000
175,000 210,000
245,000
DOE 
Capacity 
BTU/HR 
91,000  91,000 122,000
122,000
153,000
153,000 184,000
208,250
Net IBR Rating BTU/HR 
79,000 
79,000 
106,000
106,000
133,000
133,000 
160,000
181,100
Net Rating Sq. Ft. 
526 
526 
707
707
887
887 
1,067
1,207
AFUE 
Rating 
85.5 85.5 86.5
86.5
86.9
86.9 86.9
85.0
Water 
Capacity 
3.6 3.6 4.3
4.3
5.1
5.1 5.8
6.5
Approx. Shipping Weight 
300 
300 
350
350
390
390 
430
470
 
 
 
 
 
 
Cabinet Height 
28 7/8" 
28 7/8" 
28 7/8" 
28 7/8" 
28 7/8" 
28 7/8" 
28 7/8" 
Cabinet Width 
17 3/4" 
17 3/4" 
17 3/4" 
17 3/4" 
17 3/4" 
17 3/4" 
17 3/4" 
Cabinet Length 
19 1/4" 
19 1/4" 
22 3/4" 
22 3/4" 
26 1/4" 
29 3/4" 
33 1/4" 
Supply Outlet Height C.L. 
25 3/8" 
25 3/8" 
25 3/8" 
25 3/8" 
25 3/8" 
25 3/8" 
25 3/8" 
Return Outlet Height C.L. 
4 1/2" 
4 1/2" 
4 1/2" 
4 1/2" 
4 1/2" 
4 1/2" 
4 1/2" 
Flue 
Outlet 
Diameter  6" 6" 6" 6" 6" 6" 6" 
Flue Outlet Height C.L. 
20 3/4" 
20 3/4" 
20 3/4" 
20 3/4" 
20 3/4" 
20 3/4" 
20 3/4"