III. f - INSTALLING THE CONDENSATE EVAP (cont’d):
holes on the exterior bottom towards the rear of the
cabinet.  Then, using the four (4) screws provided, at-
tach the mounting rails to the cabinet bottom (the end
flange is to be up and be facing towards the cabinet
rear).   Next, place the heater into the heater bracket
(note the enclosed springs are only to be used when
the  heater  is  placed  on  the  floor).    Slide  heater  and
bracket into the mounting rails.  Plug the supplied cord
into  both  the  heater  on  one  end,  and  the  electrical
outlet provided on the cabinet exterior bottom towards
the front (see figure 4).   Screw the “U-Trap” on to the
drain line located on the rear of the cabinet and then
screw the drain extension into the “U-Trap.”
A remote model is normally supplied configured for
condensate to be run to a floor drain unless purchased
with a condensate evaporator.  The installer is respon-
sible  for  making  the  required  extension  to  the  floor
drain in accordance with good practice and local regu-
lations.
III. g - REMOTE INSTALLATION:
Remote  models  are  supplied  without  compressors,
solenoid valves, etc.  The correct voltage, amp listing
and refrigerant are listed on the unit’s serial tag.  It is
the responsibility of the installer to specify  and sup-
ply  the  correct  size  compressor(s)  based  upon  this
information and on-site requirements.  Refrigerant line
installation  must  be  done  in  accordance  with  good
practice and local regulations.  See section “III. g” for
information  concerning  condensate  removal  for  re-
mote models.
III. h - CORD & PLUG:
Most self-contained models are supplied with a cord
& plug attached.  It is shipped coiled at the top of the
cabinet, secured by a nylon strip.  For your safety and
protection, all units supplied with a cord and plug in-
clude a special three-prong grounding plug on the ser-
vice cord. Select only a dedicated electrical outlet with
grounding plug for power source.  NOTE: Do not un-
der  any  circumstances,  cut  or  remove  the  round
grounding prong from the plug, or use an extension
cord.
-3-
III. e - ROLL-IN MODEL INSTALLATION:
Roll-In cabinets set on the floor require the floor area
to be flat and level.   In addition, after the cabinet is set
in place, sealant should be used around the perimeter
of the base to comply with National Sanitation Foun-
dation requirements (see figure 3).  After sealing the
unit, the enclosed ramp should then be installed.
A stainless steel threshold ramp(s) is included to fa-
cilitate rolling in racks.  It is shipped wrapped in brown
paper and secured to the rack guides inside the cabi-
net.    To  secure  it  in  place,  remove  the  two  thumb
screws in the breaker strip near the bottom door open-
ing.  Next, loosen the thumb screws located along the
floor at the threshold.  Place the ramp(s) on top of the
loosened thumb screws and secure tabs on each end
to  breaker  strips  with  thumb  screws  previously  re-
moved.  After installing the ramp(s), it too should be
sealed to the floor.
Bumper strips are secured to the back of Roll-In mod-
els with thumb screws.  Loosen these and make them
finger-tight  to  conform  with  the  requirements  of  the
National Sanitation Foundation (NSF).
III. f - INSTALLING THE CONDENSATE EVAPORATOR:
A condensate evaporator is normally supplied on all
self-contained models (remote models require provi-
sion of either a floor drain or an optional condensate
evaporator).  On those models with the evaporator coil
compartment located on the top of the unit, the con-
densate evaporator is also secured to the top of the
cabinet.  Check that the condensate pan is under the
drain tube.
Some models, such as one-section dual-temperature
reach-in refrigerator/freezers, are supplied with a bot-
tom-mounted electric condensate evaporator.  This is
shipped in a cardboard carton secured to the cabinet
interior, and must be installed prior to use.
After the cabinet has been uncrated and the legs/cast-
ers  attached,  you  must  install  the  bottom-mounted
electric condensate evaporator.  Locate the four (4)
III. INSTALLATION (continued)
Fig. 3
SEALING BASE OF ROLL-IN MODELS
A  SEALANT  MUST  BE  USED
AROUND THE PERIMETER OF THE
BASE OF CABINET AS SHOWN TO
FULLY COMPLY WITH SANITARY RE-
QUIREMENTS.
A  RECOMMENDED  SEALANT  IS
DOW CORNING SILASTIC RTV #732
Fig. 4
U-Trap
Drain
Extension
Drain
Line
10-32 x 3/8 Screw (4)
Mounting Rails
Electric
Heater
Heater
Bracket
BMCE
Receptacle