2.5 
CONNECT USING “RE MOT E USER INTERFACE” ( RUINET) 
All configuration file transfers and system diagnostics are executed via the RUI or “Remote User Interface” which is 
installed with the Utility software.  Refer to the FieldServer Utilities manual for further information. 
 
Browse to the Remote User Interface icon in the Start menu directory and click on it. 
 
The RUI menu screen should appear. 
 
If necessary, refer to Appendix A for troubleshooting tips. 
2.6 
UPLOAD THE DEFAULT CONFIGURATION 
The  configuration  of  the  SlotServer  is  provided  to  the  FieldServer’s  operating  system  via  a  comma-delimited  file 
called  “CONFIG.CSV”.    If  ordered  with  the  SlotServer,  the  custom  configuration  is  installed;  (Reference 
documentation FS-8790-XX).  If a custom  configuration is not purchased, a template config.csv is  shipped on the 
SlotServer.  Refer to the SlotServer Configuration Manual and the Driver Manual(s)  provided with the SlotServer 
for further information on configuration files. 
 
In the main menu of the Remote User Interface screen, type “U” to upload the configuration.  Then type 
“U”  again.    The  Remote  User  Interface  Utility  will  fetch  the  default  configuration  and  put  it  into  the 
Configuration File folder (Start|Programs|FieldServerUtilities|Configuration File folder). 
2.7 
CHANGE THE CONFIGURATION FILE TO MEET THE APPLICATION 
FieldServer Technologies offers training on this topic as well as a configuration service to complete this portion of 
the work.  See www.fieldserver.com for specific details. 
 
Refer to the FieldServer Configuration Manual for instruction on writing a FieldServer configuration.  
 
Refer to the SlotServer Configuration Manual for assistance on managing the Logix driver Parameters 
 
Refer to the desired protocol Driver Supplement for assistance on managing the protocol parameters. 
2.8 
DOWNLOAD THE UPDATED CONFIGURATION FILE  
Before attempting to send files to the SlotServer, ensure that the files are in the configuration file folder.  Refer to 
the FieldServer Utilities manual for further information. 
 
From the main menu, type "D" to access the “download” menu, 
 
Type "L" (for local filename) to specify the name and extension of the file to be sent to the SlotServer.  Hit 
<Enter> when done. 
 
The Remote User Interface Utility will automatically select config.csv for  download  of csv files .  On rare 
occasions where other files need to be downloaded to the  SlotServer type “O” for other files, then type 
R” to specify the remote filename needed on the SlotServer. 
 
When satisfied that the correct file names are specified, Type "D" to download the file to the SlotServer.  
The Remote User Interface Utility will display a menu showing download progress. 
Note:  the  Remote  User  Interface  Utility  will  indicate  when  download  is  complete.    DO  NOT  reset  the  SlotServer 
before this message displays, as this could corrupt the SlotServer.