Motorola T1/E1 用户手册

下载
页码 73
Canopy  T1/E1 Multiplexer 
 
 
 
 
 
 
September 2004 
 
 
 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
 
 
 
Page 54 of 73 
3.2  T1/E1 ALARMS 
Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal 
(LOS), and alarm indication signal (AIS) detection.  
Follow these steps to display the alarms using the CLI.  
Procedure 23: Displaying the alarms using the CLI 
Action Steps 
Log in 
Press Enter. 
At the username prompt, enter admin. 
At the password prompt, enter password
View T1/E1 Alarms 
Enter get alarms
 
The system responds displays alarms for all 4 T1/E1 ports, as in the 
following example: 
 
Line1:  
    Line code violation: No 
    Receive Loss of Signal: No 
    Alarm Indication Signal Detect: No 
Line2:  
    Line code violation: No 
    Receive Loss of Signal: No 
    Alarm Indication Signal  Detect: No 
Line3:  
    Line code violation: No 
    Receive Loss of Signal: No 
    Alarm Indication Signal Detect: No 
Line4:  
    Line code violation: No 
    Receive Loss of Signal: No 
    Alarm Indication Signal Detect: No 
FPGA: 00 
 
Log off 
Enter lo
RESULT: The system responds goodbye. 
 
 end of procedure 
Issue 3