Motorola T1/E1 用户手册

下载
页码 73
Canopy  T1/E1 Multiplexer 
 
 
 
 
 
 
September 2004 
 
 
 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
 
 
 
Page 55 of 73 
Follow these steps to display the T1/E1 alarms using the EMS.  
Procedure 24: Displaying alarms using the EMS 
1. Select 
the 
Alarms
→T1/E1 Alarms menu.   
RESULT: The T1/E1 Alarms window pops up as shown in 
2.  Select the desired T1/E1 Channel (1 through 4).  
 
 end of procedure 
NOTES: 
1.  The T1/E1 alarms will be displayed, with a green light meaning no current alarms 
and a red light meaning that there is a current alarm.  The alarms are also 
displayed in text form: No means that there is not a current alarm. Yes means 
that there is a current alarm.  
2.  The Alarms Log window lists alarms that have occurred for all 4 T1/E1s while the 
window is open. An alarm log file is automatically written for all 4 T1/E1s.  The 
file exits in the same directory in which the T1/E1 Multiplexer EMS exists. The 
filename is apt1AlarmsLog.txt. The log file can be written only when the 
T1/E1 Multiplexer EMS is running. 
 
 
Figure 21: Canopy T1/E1 Mux Alarms window 
Issue 3