Advanced Entry Calibration (continued)
 Step
 Operator Action
 Displayed Message
 Comment
 
 6
 
 
 Press the                
 
key
to scroll to ‘Advanced
Entry’.
 
 
 
 
 
 
 You are entering
Advanced Entry
Calibration.
 
 
 7
 
 Press the                
 
key.
 
 
 
 
 
 Press the
 key to abort this
procedure.
 
 
 8
 
 Press the                
 
key.
 
 
 
 
 
 You are beginning
the Advanced
Entry Calibration.
 
 
 9
 
 Press the                
 
key.
 
 Place the label under the
Sensor Eye Mark and
lower the printhead
assembly.
 
 
 
 
 
 -OR-
 
 
 
 
 If using preprinted
media, ensure the
label area under
the sensor is free
of preprinted text,
graphics or
borders.
 
 
 10
 
 Press the                 key
to select the setting
(denoted by an ‘*’) and
then record the sensor
reading (the ‘yyy’ value)
in a table similar to the
one shown after Step 12,
as a Label Value.
 
 Next, press the  
key to increment the
Gain Number.
 
 Repeat this step for each
of the Gain Numbers
(00-32).
 
 
 
 
 
 -OR-
 
 
 
 
 Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.
 
 
þ
 Note: Never
position the
sensor over a
perforation when
recording a
sensor reading.