Chief Manufacturing SL-236 用户手册

下载
页码 24
1
9
Instruction Manual
SMART-LIFT 236 Electric Ceiling Lifts
11 
EXTEND 
 
Extends unit to preset travel limit. 
 
Customer within a preset maximum 
range may adjust travel limits. 
 
If using Latching Switch, be sure to 
disengage Switch prior to initiating any 
other function. 
12 
RETRACT 
 
Retracts unit to preset travel limit. 
 
Travel limits may be adjusted by 
customer within a preset maximum 
range. 
 
Momentary or Latching contact to 
Ground terminals 3, 10, 13, or 20. 
If using Latching Switch, be sure to 
disengage Switch prior to initiating any 
other function. 
13 
GROUND 
 
Ground 
 
 
 
14 
EXTEND 
ERROR 
 
Immediately reverses direction of 
travel when triggered while unit is 
extending. 
 
15 
RETRACT 
ERROR 
Immediately reverses direction of 
travel when triggered while unit is 
retracting. 
Momentary contact to Ground 
terminals 3, 10, 13, or 20. 
 
Chief Mfg. offers the SS-10 Pressure 
Sensitive Safety Strip to provide this 
function. 
Please specify how many inches required 
spanning entire pinch zone. 
The SS-10 must be ordered with the ST-15
Terminals. 
 
16 
 
EXTEND 
LIMIT 
RELAY 
 
17 
 
EXTEND 
LIMIT 
RELAY 
COMMON 
 
Closes set of internal dry contacts 
when unit reaches full extension. 
 
RATED FOR 1 AMP @ 24 VOLTS 
18 
 
RETRACT 
LIMIT 
RELAY 
 
19 
 
RETRACT 
LIMIT 
RELAY 
COMMON 
 
Closes set of internal dry contacts 
when unit reaches full retraction. 
 
RATED FOR 1 AMP @ 24 VOLTS 
 
20 
GROUND 
 
Ground 
 
 
 
 
1.0 AMP@30VDC
0.5 AMP@125VAC
0.3 AMP@60VDC
1.0 AMP@30VDC
0.5 AMP@125VAC
0.3 AMP@60VDC