Huawei MC509 用户手册

下载
页码 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
SAR Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
131 
 
13 
SAR  Commands 
13.1 ^BODYSARON–Disable or Enable Body SAR   
13.1.1 Syntax 
Command 
Possible Response(s) 
^BODYSARON=<on
In case of successful execution:     
<CR><LF>OK<CR><LF> 
In case of an error during command execution: 
<CR><LF>ERROR<CR><LF> 
^
BODYSARON
?
 
In case of successful execution:   
<CR><LF>^
BODYSARON
:<on><CR><LF> 
<CR><LF>OK<CR><LF> 
In case of an error during command execution: 
<CR><LF>ERROR<CR><LF>
 
^BODYSARON=? 
<CR><LF>^BODYSARON:(0,1)<CR><LF> 
<CR><LF>OK<CR><LF> 
 
13.1.2 Interface Description 
This command is used to enable or disable the BodySAR function. Read command 
can queries current state for BodySAR function, Test command returns supported 
value of set command.   
13.1.3 Parameter Description 
< on>: state of BodySAR function 
0: disable Body SAR (default). 
1: Enable Body SAR.