Seamless Switch: This feature allows for high-speed switching between any two 
PlasmaView inputs using the SWAP button on the remote control. To enable it, select 
Seamless Switch from the Option menu and set it to ON. Then, specify the two inputs you 
want to associate with this feature in the SELECT1 and SELECT2 fields. 
By default, Input 1 and Input 2 are selected, so that when Input 1 is active, pressing SWAP 
switches to Input 2 and vice versa. 
Select Return to exit the Seamless Switch menu. 
Picture Orient.: Select Picture Orient. to change the displayed image orientation to suit the 
installation method; see Figure 4-8. For example, if the PlasmaView is suspended from a 
ceiling, you may want to mount it upside down and run the cables upward (toward the 
ceiling) to make them less visible. In this case, you would select “FLIP HV.” 
Figure 4-8. Picture Orientation
Function Reset: To restore the PlasmaView to its factory-default state, select Function Reset 
from the Option menu. Then, press 
 to highlight YES and press SET. This action resets ALL 
settings (except the display ID Number) to their default values, as set at the factory. 
Seamless Switch is not available when using PIP. 
This action is not undoable. Proceed with caution! 