Vidikron VP-6000 用户指南

下载
页码 84
Vidikron PlasmaView Owner’s Operating Manual
43 
PRE
L
IMINAR
Y
Auto Function: The PlasmaView can automatically switch to Input 1 when an image signal is 
detected at that input. To enable this feature, select Auto Function from the Option menu 
and set it to INPUT 1. 
After Auto Function triggers an input switch, when the Input 1 signal is no longer present, 
the input source reverts to the previously-selected input. 
Option (Installer Adjust 
Mode)
Screen Maint.: When in Installer Adjust mode, select Screen Maint. from the Option menu 
to program the screen maintenance features of the PlasmaView to operate at regular 
intervals. This is useful for preventing image burn-in. 
You can program the PlasmaView to switch inputs and/or replace the normal source signal 
with a white field, an inverse image or an “orbiting” image. You can specify a time of day and 
day of the week when you want this to take place. 
To set up a screen maintenance program:
1.
Press SET to select the DATE field for the first program. Press 
 or 
 to select one of the 
following:
• SUN, MON, TUE, WED, THU, FRI or SAT for a program that runs once only on the next 
occurrence of that day. 
• * for a program that runs daily.
• *SUN, *MON, *TUE, *WED, *THU, *FRI or *SAT for a program that runs weekly on that 
day. 
2.
Press SET, then 
 followed by SET again to set the program start time.
3.
Press 
 or 
 to set the hour component of the start time. 
4.
Press 
then 
 or 
 to set the minute component of the start time. 
5.
Press SET, then 
 followed by SET again to set the program end time (repeat steps 3 
and 4).
6.
Press SET, then 
 followed by SET again to specify an input associated with this 
program. Choose “–” to specify the input that was active when the PlasmaView was last 
powered off. 
7.
Press SET, then 
 followed by SET again to select the PATTERN field for this program. 
Press 
 or 
 to select one of the following:
• Choose “–” to specify the function that was active when the PlasmaView was last 
powered off. 
• Choose WHITE to display a white field. 
• Choose INVERSE to display an inverse image.
• Choose ORBITER to display an “orbiting” image. 
8.
Press SET.
9.
Repeat steps 1 through 8 as desired to create additional screen maintenance programs. 
The input signal must be RGB with composite or separate sync; Auto 
Function will not work with sync-on-green RGB or component signals. 
When Auto Function is active, selecting an input manually causes Auto 
Function to be temporarily disabled. If you cycle power to the 
PlasmaView, Auto Function becomes active again. 
Note
INPUT 3
INSTALLER ADJ.
SCREEN
SET-UP
OPTION
PICTURE
SET
SET
EXIT
MENU
:  OFF
:  9600BPS
:  01H
SCREEN MAINT.
TEST PATTERN
SIDEBAR ADJ.
BAUD RATE
ID NUMBER
SCREEN MAINT.
DATE ON 
OFF 
INPUT  PTRN.
10:00 
– –:– – 
– 
20:00 
– –:– – 
– 
WHITE
* – 
–:– 
– 
21:00  –  –
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
   RETURN
SEL.
ADJ.
SET
EXIT