Aiphone RY-24L 用户手册

下载
页码 3
Page 2
WIRING DIAGRAMS (cont):
KB & KC System Wiring
1A1
1A2
Master
KB-3MRD
B1
B2
2A1
2A2
3A1
3A2
CN11
Org
Yel
+
-
PS-2420UL
+
-
A2
KB-DAR
A1
LOCK 
POWER
Red
Blk
Brn
Org
Yel
ELECTRIC STRIKE 
WIRING METHOD:
(Normally Open contact)
Connect 
YELLOW 
wire of CN11 
directly to + 
on unit.
Red
Blk
Brn
Org
Yel
COM
N/C
MAGNETIC LOCK 
WIRING METHOD:
(Normally Closed contact)
Use Brown & Yellow wires 
when connecting to Maglock.
LOCK 
POWER
To (-) of 
power supply
Connect Red 
to Orange 
lead of Master
+
-
+
-
LOCK 
POWER
KC-DAR
A1
A2
PS-2420UL
+
-
1A1
1A2
KC-1GRD
KC-1MRD
B2
+
-
S
S
B1
Red
Blk
Brn
Org
Yel
ELECTRIC STRIKE 
WIRING METHOD:
(Normally Open contact)
Connect 
YELLOW 
wire of CN11 
directly to + 
on unit.
Yel
Org
COM
N/O
NOTE: The door release contacts are rated at 12V AC, 400mA.  The RY-24L should be used in any application where the 