0210JD
SPECIFICATIONS:
Power Source:
Supplied by master station or CEU
Mounting:
No mounting required
Terminations:
Color-coded prewired pigtails
Relay Input:
24V DC, Red and Black wires, 22AWG
Relay Output: 
Brown, Red, Orange wires, 18AWG
N/O Output rating:
5A at 30V DC or 125V AC
N/C Ouptut rating: 
3A at 30V DC or 125V AC
Wiring:
conductors from unit’s door release contacts to RY-24L. 
2 conductors from RY-24L to release mechanism, with power wired in series.
Dimensions (HxWxD):  1-3/4"  x  7/8" x  7/16", with wires extending approx. 7-1/2"
D1      D3      D5      D7
D2      D4      D6      D8
DOOR RELEASE RELAY
L1   L2   L3   L4   L5   L6   L7   L8 
M1     M3
M2      M4
VCH1 VCH2
X1 OUT X2
AX-320C
CO
+ -     + -
D-PS V-PS
RS-232C
POWER
VIDEO OUT
V1        V2
AIPHONE  AX-084C
AX-8MV
Master #1
AX-DV
Door #1
PS-
2420UL
+
-
PS-
2420UL
+
-
Connect separate RY-24L relay for each door release contact being used.
WIRING DIAGRAMS (cont):
AX-DV
Door #2
AX System Wiring
R
e
d
Blk
Brn
Org
Yel
COM
N/O
Use Brown &  Orange wires when 
connecting to Electric Strike.
LOCK 
POWER
R
e
d
Blk
Brn
Org
Yel
COM
N/C
Use Brown & Yellow wires when 
connecting to Maglock.
LOCK 
POWER
NOTE: The door release contacts are rated at 24V AC/DC, 
500mA.  The RY-24L should be used in any application where 
the strike or maglock has a higher voltage or draws more 
current. Otherwise, internal damage to the AX Exchange Unit  
could result.