16-Channel Digital Video Recorder 
 
 
 
RS485 Port 
 
 
Connector Pin Outs: 
Master Unit 
Slave Unit
 
→     To    →
TX+/RX+
 
→     To    →
TX-/RX-
 
GND 
→     To   →
GND
 
Alarm Input/Output 
 
 
AI 1 to 16 (Alarm-In):  You can use external devices to signal the DVR to react to events.  Mechanical or electrical 
switches can be wired to the AI (Alarm-In) and GND (Ground) connectors.  The threshold voltage of electrical switches 
for NC (Normally Closed) is above 2.4V and for NO (Normally Open) is below 0.3V, and should be stable at least 0.5 
seconds to be detected.  The voltage range of alarm input is from 0V to 5V.  See Chapter 3 ─ Configuration for 
configuring alarm input. 
 
GND (Ground):  Connect the ground side of the Alarm input and/or alarm output to the GND connector. 
 
NOTE:  All the connectors marked GND are common. 
 
NO (Normally Open):  Connect the device to the COM and NO (Normally Open) connector.  NO is a relay output 
which sinks 1A@30VDC (NO).  See Chapter 3 ─ Configuration for configuring alarm output. 
 
Connector Pin Outs: 
Alarm In (1 to 16) 
Alarm Inputs 1 to 16
 
GND 
Chassis Ground
 
COM 
Common
 
NO
Alarm Out (Normally Open)
 
Network Port 
 
 
CAUTION:  The network connector is not designed to be connected directly with cable or wire 
intended for outdoor use.
 
Factory Reset Switch 
 
 
The DVR has a Factory Reset switch to the right of the VGA connector on the rear panel.  
This switch will only be used on the rare occasions that you want to return all the settings to 
the original factory settings. 
 
CAUTION:  When using the Factory Reset, you will lose any settings you have saved. 
 
 
The DVR can be controlled remotely by an external device or control system, such as a control keyboard, 
using RS485 half-duplex serial communications signals.  The RS485 connector can also be used to control 
PTZ (pan, tilt, zoom) cameras or text-in devices.  Connect RX+/TX+ and RX-/TX- of the control system 
to the P (+) and N (–) (respectively) of the DVR.  See Chapter 3 ─ Configuration and the PTZ camera, 
text-in device or remote controller manufacture’s manual for configuring the RS485 connection. 
 
NOTE:  To make connections on the Alarm Connector Strip, press and hold the 
button and insert the wire in the hole below the button.  After releasing the 
button, tug gently on the wire to make certain it is connected.  To disconnect 
a wire, press and hold the button above the wire and pull out the wire.
 
 
The DVR can be networked using the 10/100Mb Ethernet connector.  Connect a Cat5 cable with an RJ-45 
jack to the DVR connector.  The DVR can be networked with a computer for remote monitoring, searching, 
configuration and software upgrades.  See Chapter 3 ─ Configuration for configuring the Ethernet 
connections.