Speco Technologies CS16 用户手册

下载
页码 83
16-Channel Digital Video Recorder 
 
25 
 
 
 
 
Figure 25 — Pre-Event setup screen. 
When the DVR is in the Event Record mode it is possible to 
have it record images before the event occurs.  The Pre-Event 
screen allows you to define how to handle pre-event recording. 
 
You can turn individual cameras On or Off for pre-event 
recording.  The image speed can be set from 1.00 to 30.00 ips 
(25.00 ips PAL), image quality can be selectable from Very 
High, High, Standard and Basic, and image resolution can 
be selectable from Very High (D1), High (Half D1) and 
Standard (CIF). 
 
You can set the amount of time to record prior to the event 
by adjusting the Dwell.  You can set the Dwell from 5 seconds 
to 30 minutes.  The longer the dwell set, the fewer maximum 
ips can be set. 
 
NOTE:  When the DVR is in the Time or Time & Event mode, it ignores the pre-event settings and follows the 
time settings. 
 
 
Event Setup 
 
 
 
Figure 26 — Event menu. 
 
Alarm-In
 
 
Highlight Alarm-In in the Event menu and press the   button.  The Alarm-In setup screen appears. 
 
 
 
Figure 27 — Alarm-In Settings screen. 
The alarm terminal strip on the back of the DVR has inputs 
associated with each alarm.  You can set up each input on the 
Alarm-In screen.  You can turn each input On or Off by 
highlighting the alarm number and pressing the   button. 
 
Each input can be given a title.  Highlight the desired Title box 
and press the   button.  A virtual keyboard appears allowing 
you to enter a title name. 
 
Each input can be set as NO (normally open) or NC (normally 
closed). 
 
You can set up the DVR to start panic recording whenever it senses an input on one of its alarm input connectors.  Highlight 
the box beside Panic Record and press the   button.  A list of Alarm Inputs appears, and you can select which alarm 
input you want associated with panic recording.  The DVR will continue panic recording until an input on the selected 
alarm input is released as long as   (Panic) in the Live Monitoring menu is not selected to stop the panic recording.