4-4
Manual Calibrations
Media Feed Calibration
This calibration allows you to calibrate the accuracy of the 
media feed process. You perform this calibration when loading 
media, or later if prints requiring very accurate length (for exam-
ple, output that will be tiled) are found to be the wrong length.
To perform this procedure, it is helpful to have a magnifying 
glass or printer’s loupe to examine the test patterns.
◆ Before performing a Media Feed calibration, print the Prime 
Bars and clean the ink jets to get the maximum number of 
jets working. 
◆ After performing a Media Feed calibration, run AutoSet.
1.
If you will be performing this calibration with a new roll of 
media, advance the media to the floor, back it up to the 
platen, and remove the supply loop (see page 2-13).
This will remove the advance error that would be introduced 
by the tighter winding at the beginning of a new roll of 
media.
2.
Press the 
v (Menu) key from the Front Page screen on the 
control panel to display the menus.
3.
Press the 
E (Menu In) key display the Calibrate Printer menu.
4.
Press the 
p key to highlight Manual Calibration.
5.
Press the 
E (Menu In) key.
6.
Press the 
E (Menu In) key to select the Media Feed option.
The following prompt appears:
Press Proceed to print pattern
Press Cancel to adjust without printing
7.
Press the Proceed key to print a test pattern, or Cancel to skip 
printing.
If you press Cancel, to go step 13.
When you press Proceed, you can choose between the fol-
lowing calibrations:
◆ 34-Inch (900 mm) Calibration — prints two reference 
marks along the direction of media feed; measure the 
distance between the marks to determine advance 
accuracy.
◆ 12-Inch (305 mm) Calibration — same as previous cali-
bration, uses less media but may be less accurate.