HP (Hewlett-Packard) 0706124 REV B 用户手册

下载
页码 150
Manual Calibrations
4-5
◆ Double Lines — alternate method for use when a refer-
ence measuring stick is not available
8.
Select one of the options and press the 
E (Menu In) key to 
continue.
9.
Follow the applicable procedure below.
34-Inch/12-inch Calibration
10. Press the 
B key to continue.
The printer asks whether you want to print the media feed 
calibration.
11. Press the 
B key to continue.
The printer prints the calibration marks, and prompts you to 
adjust the advance.
12. With a metal yardstick, measure the distance between the 
marks.
A measuring stick with 1/64 inch markings works best.
13. Adjust the media feed advance using the control panel.
You can increase the advance by pressing the 
C key, or 
decrease it by pressing the 
p key.
14. Press 
B (Proceed) to save the advance value you entered.
15. Press 
B (Proceed) to return to the menu.
Fig. 4-16. Media Feed Calibration pattern