Ciprico 4105 Series 用户手册

下载
页码 131
MV 4105_Ciprico Inc. 
                                                                                                                    
8-5
MediaVault 4105 User Manual                                                                                                          Maintenance
Install and Rebuild a Disk Drive Module 
For Disk Drive Modules in RAID 0 Mode
A failed disk drive module in RAID 0 mode is indicated by a series of 
beeps. The beep indicate the number of the drive that failed. As the beeps 
occur, the LED nearest the defective disk drive module is illuminated.
1.
Gently insert the new disk drive module into the bay.
2.
Push down on the handle while pushing the disk drive module inwards, 
until a “click” is heard.
3.
Reinstall the front panel of the MV 4105.
4.
Apply power to the MV 4105 (the beeps should no longer be heard).
5.
Apply power to the host computer. 
Format/partition/stripe the array using the procedures described in 
Chapter 6, Configuration. Restore data to the array if a backup is 
available.
CAUTION: The previous volume might appear on 
the monitor. Do not attempt to use this volume! 
The data on this volume is corrupt
.