Sanyo CH3632 Benutzerhandbuch

Seite von 106
1
2
3
4
 – 13 –
SM830076
1. Specifications
1-2
Major Component Specifications
(B)
Outdoor Unit
MODEL No.
CH2432
Source
230 - 208 VAC / 1 phase / 60 Hz
Controller P.C.B. Ass'y
CR - CH2432 (Microprocessor)
Control circuit fuse
250 VAC, 3 A
Compressor
Rotary (Hermetic)
Model
C - 2R160H6T
Source
230 - 208 VAC / 1 phase / 60 Hz
Nominal output
W
1,700
Compressor oil
cc
800
Coil resistance (Ambient temperature 77 
°
F)
Ω
C – R : 0.885 , C – S : 1.773
Safety device
Internal type
Overload relay models
Operating temperature
Open
°
F
297
±
9
Close
°
F
198
±
20
Operating ampere (at 77 
°
F)
A
Run capacitor
VAC,
µ
F
400 VAC, 40 
µ
F
Crank case heater
VAC,
W
230 VAC, 30 W
Refrigerant amount charged at shipment
lbs.
(kg)
R22 : 6.17 (2.8)
High pressure switch
ACB - 1UB11
Set pressure
OFF lb/in
2
(kg/cm
2
)
426.6
(30           )
ON
lb/in
2
(kg/cm
2
)
341.3  
±
  28.44 (24  
±
  2.0)
Fan
Propeller
Number...diameter
in.
(mm)
1 ... 18 - 3/32 (460)
Fan speeds
2 (AUTO)
Fan motor
Model
KFC6T - 91D6P
Source
230 - 208 VAC / 1 phase / 60 Hz
No. of pole ..... rpm (230 V, High)
6 ... 879
Nominal output
W
110
Coil resistance
Ω
BRN – WHT : 67.14 , VLT – YEL : 11.42
(Ambient temperature 68 
°
F)
WHT – VLT
: 64.85 , YEL – PNK : 10.60
Safety device
Internal type
Operating temperature
Open
°
F
248
±
9
Close
°
F
171
±
27
Run capacitor
VAC,
µ
F
440 VAC, 4 
µ
F
Heat exchange
Coil
Aluminum plate fin / Copper tube
Rows ..... Fins per inch
2 ... 14.1
Face area
ft.
2
(m
2
)
6.78 (0.63)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
+ 28.44
+ 7.11
+  2.0
+  0.5