Instructions for the installer
 
 
 
33 
5.3 
Regulation for LPG 
 
 
 
 
 Check that the connection has been made as described in the “Gas 
connection” section. 
Undo the screw “D” and push the air regulator “C” fully down. Use a 
spanner to remove the nozzles “B” and fit those of suitable type 
following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm. 
Regulate the air flow by moving the Venturi pipe “C”, until the gap “A” is 
as shown in the table in point “5.5  Regulation of primary air” and fix it 
with the screw “D”.  After making the adjustments, restore the seals with 
sealing wax or an equivalent material.
 
 
   
 
 
 
 
 
   
Burner 
 
Rated 
heating 
LPG – G30/G31 28/37 mbar 
capacity
 
 
Nozzle 
Diameter 
1/100 
mm 
By-pass 
1/100 
mm 
[V
(1)
By-pass 
1/100 
mm 
[NV
(1)
Reduced
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
 
Auxiliary 
 
1.05 
48 
30 
30 
450 
76 
75 
 
Semi-rapid 
 
1.8 
62 
32 
32 
500 
131 
129 
 
Rapid 
 
2.55 
76 
42 
42 
750 
185 
182 
 
Rapid large 
 
3.1 
85 
45 
45 
850 
225 
222 
 
Fish pan 
 
2.9 
82 
50 
50 
950 
211 
207 
 
Ultra rapid 
 
4.0 
95 
63 
65 
1600 
291 
286 
 
(1) 
V = Valved; NV = Nonvalved