Smeg AP64S3 Benutzerhandbuch

Seite von 20
 
Instructions for the installer 
 
32 
 
 
5  ADAPTATION TO DIFFERENT TYPES OF GAS 
 
   
  Before performing any cleaning or maintenance work, disconnect the 
appliance from the electrical socket. 
 
 
   
 
  The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. For functioning with other types of gas the nozzles must be 
replaced and the primary air adjusted. 
To replace the nozzles and regulate the burners, you have to remove 
the top as described in the following paragraph. 
 
   
 
 
5.1 
Removing the separable control panel
 
(models with 
separable control panel) 
 
 
 
  
1.
  Remove the knobs and the knob guard 
tube “A” by pulling them up; 
2.
  Use a crosshead screwdriver to remove 
the screws and the two cylindrical 
supports “B”; 
3.
  Raise the left-hand side of the control 
panel slightly and shift it to the right to 
remove it completely; 
4.
  In models with electric hotplate, the body 
of the pilot light has to be removed to free 
the control panel; 
 
  
 
 
   
 
 
5.2 
Removing the hob
 
(models with integrated control 
panel) 
 
 
 
 
  1.  Remove the knobs, the 
griddles, the burner caps, the 
flame caps and the two rear 
plugs; 
2.
  Remove the screws “A” 
which fix the burner supports;
3.
  Raise the hob, sliding it off 
the ignition plugs and/or the 
thermocouples and the gas 
tap rods;