Hearth & Home Technologies 823-0290 Benutzerhandbuch

Seite von 32
Page 9
Isle Royale Wood Stove
R
September 1, 2008
250-5763C
REVERSIBLE FLUE COLLAR
The flue collar is reversible for either a top or rear venting 
installation.  The unit is shipped with the flue collar in the top 
vent position.  
CONVERTING COLLAR FOR REAR VENT INSTALLATION
1.  Remove 5 Phillips head screws from the rear shield, lift 
shield up and set aside. 
2.  Remove  bolts  from  each  side  of  the  flue  transition  (2 
total).  (Place your free hand in flue opening to locate 
and retrieve nuts attached to bolts.) 
3.  Turn vent to horizontal position. Inspect sealant to ensure 
a leak free application.
4.  Re-assemble in reverse order.
Mounting Screws
Bend Flange Down
Please note this cover plate will not 
work with the Low-Profile Kit
REAR FLUE DEFLECTOR COVER PLATE
This cover plate is used when the flue collar is turned for a 
rear vent application.
2.  Bend the cover plate flange down.
3.  Secure the cover plate with the remaining two screws.
1.  After the flue collar has been reversed for a rear vent 
installation,  install  the  cover  plate  on  the  stove  with  the 
two screws provided.