Chassis and Stacking 
164
M6100, M5300, and M7100 Series Managed Switches 
The following table describes the nonconfigurable Backplane-port packet-path data that is 
displayed. 
Configure the Chassis Power Settings
To configure the chassis power settings:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.
7. 
Click System > Chassis > Advanced > Chassis Power Configuration.
8. 
Select the Power Module Redundancy Enable or Disable radio button.
This specifies whether power redundancy mode is enabled or disabled.
9. 
Click the Apply button.
Table 61.  Backplane-port Packet-path
Field
Description
Direction
The path direction.
Packet-path
The packet path.