HE360 HUMIDIFIER AND INSTALLATION KIT
69-2631ES—03
12 
WIRING
CAUTION
Hazardous Voltage. 
Can cause personal injury or equipment damage.
Disconnect power supply before installing or servicing equipment.
IMPORTANT
— Use 
THIS wiring diagram—NOT the one supplied with humidistat instructions.
— All wiring must comply with applicable local code, ordinances and regulations.
Wire the humidifier solenoid valve, pressure switch and humidistat. See Fig. 12.
NOTE: It is acceptable to switch the position of the red and white wires when 
wiring the equipment.
Fig. 12. Wiring the controls.
1. Run the two-strand thermostat wire from the humidifier to the humidistat, and 
from the humidistat to the pressure switch.
2. Cut two (2) lengths of thermostat wire to reach between components, leaving 
adequate wire at both ends for connections.
NOTE: Humidistat and pressure switch can be wired in any order.
3. At the humidifier, use one length of thermostat wire to connect a red wire to one 
of the yellow humidifier wires and a white wire to the remaining yellow humidifier 
wire.
 (The red wires from the humidifier are not used.)
4. At the pressure switch, use the remaining length of thermostat wire to connect a 
red wire to the C terminal and a white wire to the NO terminal using spade con-
nectors and pliers. (The NC terminal is not used.)
5. Connect the white wires from each length of thermostat wire to each of the black 
wires of the humidistat using wire nuts.
6. Connect the remaining red wires together using a wire nut.
M34590
Humidity Control
Régulateur d'humidité
-20 ¡F
-10 ¡F
0 ¡F
+10 ¡F
+20 ¡F
Over 20 ¡F
15%
20%
25%
30%
35%
40%
HUMIDITY
SETTING
OUTDOOR
TEMPERATURE
-30 ¡C
-25 ¡C
-20 ¡C
-10 ¡C
-5 ¡C
Over 0 ¡C
HUMIDISTAT
AIR PRESSURE 
SWITCH
YELLOW
YELLOW
RED
WHITE
BLACK
BLACK
RED
WHITE
WHITE
HUMIDIFIER
RED
WHITE
RED